Active differential probe 70V, 50 MHz, x1/10, CAT I
TA058 differential oscilloscope probe specifications
- Bandwidth: DC to 50 MHz (–3 dB)
- Attenuation ratio: 10:1
- Accuracy: ±1%
- Rise time: < 7 ns
- Input impedance : 1.6 MΩ || 7 pF each side to ground
- Input Voltage
- Differential range: ±70 V (DC + Peak AC) or 70 V RMS
- Common mode range: ±700V (DC + Peak AC) or 600 V RMS
- Absolute max. voltage (either input to ground): ±700 V (DC + Peak AC) or 600 V RMS CAT I
- Output
- Swing (into 5 k? load): ±7 V
- Offset (typical): < ±2 mV
- Noise (typical) : 0.7 mV RMS
- Source impedance (typical): 50 Ω
- CMRR (typical): 95 dB @ 60 Hz; 60 dB @ 1 MHz
The TA058 is a 50 MHz bandwidth active differential probe suitable for ±70 V (DC + peak AC) differential measurements in the presence of common-mode voltages up to ±700 V (DC + peak AC).
This differential probe extends the functionality of standard single-ended input oscilloscopes to allow a safe and accurate method of making high-voltage differential measurements. Applications include making safe measurements in power circuit applications and acquisition of low-speed balanced differential signals found in serial communications buses.
The TA058 is a 50 MHz bandwidth active differential probe suitable for ±70 V (DC + peak AC) differential measurements in the presence of common-mode voltages up to ±700 V (DC + peak AC).
This differential probe extends the functionality of standard single-ended input oscilloscopes to allow a safe and accurate method of making high-voltage differential measurements. Applications include making safe measurements in power circuit applications and acquisition of low-speed balanced differential signals found in serial communications buses.