| Passive Probes |
|---|
| MSP510 Passive Probe 500 MHz, 10:1 |
| SigOFIT Optical-fiber Isolated Probes |
|---|
| MOIP1000P SigOFIT Optical-fiber Isolated Probe 1 GHz Bandwidth |
| MOIP500P SigOFIT Optical-fiber Isolated Probe 500 MHz Bandwidth |
| MOIP350P SigOFIT Optical-fiber Isolated Probe 350 MHz Bandwidth |
| MOIP200P SigOFIT Optical-fiber Isolated Probe 200 MHz Bandwidth |
| High Voltage Differential Probes DP Series |
|---|
| DP7002 High voltage differential probe 700 V (100X), 7000 V (1000X), 200 MHz |
| DP7000 High voltage differential probe 700 V (100X), 7000 V (1000X), 100 MHz |
| DP3005 High voltage differential probe 300 V (100X), 3000 V (1000X), 500 MHz |
| DP3002 High voltage differential probe 300 V (100X), 3000 V (1000X), 200 MHz |
| DP3000 High voltage differential probe 300 V (100X), 3000 V (1000X), 100 MHz |
| DP1500 High voltage differential probe 150 V (50X), 1500 V (500X), 100 MHz |
| DP1505 High voltage differential probe 150 V (50X), 1500 V (500X), 500 MHz |
| DP1502 High voltage differential probe 150 V (50X), 1500 V (500X), 200 MHz |
| DP705 High voltage differential probe 70 V (20X), 700 V (200X), 500 MHz |
| DP702 High voltage differential probe 70 V (20X), 700 V (200X), 200 MHz |
| DP700 High voltage differential probe 70 V (20X), 700 V (200X), 100 MHz |
| Current Probes CP and ACP Series |
|---|
| Micsig CP2100A AC/DC current probe 800 kHz, 10 Apk/100 Apk, BNC port |
| Micsig CP2100B DC/AC Current probe 2.5 MHz, 10 Apk/100 Apk, BNC port |
| Micsig CP1510 HF DC/AC current probe DC/AC 30 A/150 A 10 MHz, BNC port |
| Micsig CP3005 HF DC/AC current probe, DC/AC 50 A/300 A 5 MHz, BNC port |
| Micsig CP3008 HF DC/AC current probe, DC/AC 50 A/300 A 8 MHz, BNC port |
| Micsig CP503B HF DC/AC current probe DC/AC 5 A/30 A 50 MHz BNC port |
| Micsig CP1003B HF DC/AC current probe DC/AC 6 A/30 A 100 MHz BNC port |
| Micsig ACP1000 AC Current probe 10 Hz-100 kHz, 0.1 Apk-1000 Apk BNC port |
| Rogowski Current Probes RCP-XS Series (1.5 kV Isolation voltage) |
|---|
| RCP60XS-80 Rogowski current probe. Peak Current 60 Apk, 70 Hz -30 MHz, Sensitivity 100 mV/A (10X), Peak di/dt 4 kA/us, Coil diameter 1.6 mm; length 80 mm |
| RCP120XS-80 Rogowski current probe. Peak Current 120 Apk, 34 Hz-30 MHz, Sensitivity 50 mV/A (20X), Peak di/dt 8 kA/us, Coil diameter 1.6 mm; length 80 mm |
| RCP300XS-80 Rogowski current probe. Peak Current 300 Apk, 10 Hz-30 MHz, Sensitivity 20 mV/A (50X), Peak di/dt 20 kA/us, Coil diameter 1.6 mm; length 80 mm |
| RCP600XS-80 Rogowski current probe. Peak Current 600 Apk, 8 Hz-30 MHz, Sensitivity 10 mV/A (100X), Peak di/dt 40 kA/us, Coil diameter 1.6 mm; length 80 mm |
| RCP1200XS-80 Rogowski current probe. Peak Current 1200 Apk, 5 Hz-30 MHz, Sensitivity 5 mV/A (200X), Peak di/dt 70 kA/us, Coil diameter 1.6 mm; length 80 mm |
| RCP3000XS-80 Rogowski current probe. Peak Current 3000 Apk, 4 Hz-30 MHz, Sensitivity 2 mV/A (500X), Peak di/dt 70 kA/us, Coil diameter 1.6 mm; length 80 mm |
| RCP6000XS-80 Rogowski current probe. Peak Current 6000 Apk, 4 Hz-30 MHz, Sensitivity 1 mV/A (1000X), Peak di/dt 70 kA/us, Coil diameter 1.6 mm; length 80 mm |
| RCP300XS-200 Rogowski current probe. Peak Current 300 Apk, 10 Hz -20 MHz, Sensitivity 20 mV/A (50X), Peak di/dt 20 kA/us, Coil diameter 1.6 mm; length 200 mm |
| RCP600XS-200 Rogowski current probe. Peak Current 600 Apk, 7 Hz -20 MHz, Sensitivity 10 mV/A (100X), Peak di/dt 40 kA/us, Coil diameter 1.6 mm; length 200 mm |
| RCP12000XS-80 Rogowski current probe. Peak Current 12000 Apk, 2 Hz-30 MHz, Sensitivity 0.5 mV/A (2000X), Peak di/dt 70 kA/us, Coil diameter 1.6 mm; length 80 mm |
| RCP1200XS-200 Rogowski current probe. Peak Current 1200 Apk, 5 Hz -20 MHz, Sensitivity 2 mV/A (200X), Peak di/dt 70 kA/us, Coil diameter 1.6 mm; length 200 mm |
| RCP6000XS-200 Rogowski current probe. Peak Current 6000 Apk, 3 Hz -20 MHz, Sensitivity 1 mV/A (1000X), Peak di/dt 70 kA/us, Coil diameter 1.6 mm; length 200 mm |
| Rogowski Current Probes RCP-S Series (3 kV Isolation voltage) |
|---|
| RCP120S-200 Rogowski current probe. Peak Current 120 Apk, 14 Hz - 25 MHz, Sensitivity 50 mV/A (20x), Peak di/dt 8 kA/us, Coil diameter 3 mm; length 200 mm |
| RCP300S-200 Rogowski current probe. Peak Current 300 Apk, 7 Hz - 25 MHz, Sensitivity 20 mV/A (50X), Peak di/dt 20 kA/us, Coil diameter 3 mm; length 200 mm |
| RCP600S-200 Rogowski current probe. Peak Current 600 Apk, 5 Hz - 25 MHz, Sensitivity 10 mV/A (100X), Peak di/dt 40 kA/us, Coil diameter 3 mm; length 200 mm |
| RCP1200S-200 Rogowski current probe. Peak Current 1200 Apk, 5 Hz - 25 MHz, Sensitivity 5 mV/A (200X), Peak di/dt 70 kA/us, Coil diameter 3 mm; length 200 mm |
| RCP3000S-200 Rogowski current probe. Peak Current 3000 Apk, 3 Hz - 25 MHz, Sensitivity 2 mV/A (500X), Peak di/dt 70 kA/us, Coil diameter 3 mm; length 200 mm |
| RCP6000S-200 Rogowski current probe. Peak Current 6000 Apk, 2 Hz - 25 MHz, Sensitivity 1 mV/A (1000X), Peak di/dt 70 kA/us, Coil diameter 3 mm; length 200 mm |
| RCP6000S-700 Rogowski current probe. Peak Current 6000 Apk, 3 Hz-10 MHz, Sensitivity 1 mV/A (1000X), Peak di/dt 70 kA/us, Coil diameter 3 mm; length 700 mm |
| RCP12000S-700 Rogowski current probe. Peak Current 12000 Apk, 2 Hz-10 MHz, Sensitivity 0.5 mV/A (2000X), Peak di/dt 70 kA/us, Coil diameter 3 mm; length 700 mm |
| Rogowski Current Probes RCP-M Series (5 kV Isolation voltage) |
|---|
| RCP120M-200 Rogowski current probe. Peak Current 120 Apk, 14 Hz - 25 MHz, Sensitivity 50 mV/A (20X), Peak di/dt 8 kA/us, Coil diameter 4.5 mm; length 200 mm |
| RCP300M-200 Rogowski current probe. Peak Current 300 Apk, 7 Hz - 25 MHz, Sensitivity 20 mV/A (50X), Peak di/dt 20 kA/us, Coil diameter 4.5 mm; length 200 mm |
| RCP600M-200 Rogowski current probe. Peak Current 600 Apk, 5 Hz - 25 MHz, Sensitivity 10 mV/A (100X), Peak di/dt 40 kA/us, Coil diameter 4.5 mm; length 200 mm |
| RCP1200M-200 Rogowski current probe. Peak Current 1200 Apk, 5 Hz - 25 MHz, Sensitivity 5 mV/A (200X), Peak di/dt 70 kA/us, Coil diameter 4.5 mm; length 200 mm |
| RCP3000M-200 Rogowski current probe. Peak Current 3000 Apk, 3 Hz - 25 MHz, Sensitivity 2 mV/A (500X), Peak di/dt 70 kA/us, Coil diameter 4.5 mm; length 200 mm |
| RCP6000M-200 Rogowski current probe. Peak Current 6000 Apk, 2 Hz - 25 MHz, Sensitivity 1 mV/A (1000X), Peak di/dt 70 kA/us, Coil diameter 4.5 mm; length 200 mm |
| RCP6000M-700 Rogowski current probe. Peak Current 6000 Apk, 3 Hz-10 MHz, Sensitivity 1 mV/A (1000X), Peak di/dt 70 kA/us, Coil diameter 4.5 mm; length 700 mm |
| RCP12000M-700 Rogowski current probe. Peak Current 12000 Apk, 2 Hz-10 MHz, Sensitivity 0.5 mV/A (2000X), Peak di/dt 70 kA/us, Coil diameter 4.5 mm; length 700 mm |
| Rogowski Current Probes RCP-L Series (10 kV Isolation voltage) |
|---|
| RCP600L-700 Rogowski current probe. Peak Current 600 Apk, 8 Hz - 10 MHz, Sensitivity 10 mV/A (100X), Peak di/dt 70 kA/us, Coil diameter 8 mm; length 700 mm |
| RCP1200L-700 Rogowski current probe. Peak Current 1200 Apk, 5 Hz - 10 MHz, Sensitivity 5 mV/A (200X), Peak di/dt 70 kA/us, Coil diameter 8 mm; length 700 mm |
| RCP3000L-700 Rogowski current probe. Peak Current 3000 Apk, 4 Hz - 10 MHz, Sensitivity 2 mV/A (500X), Peak di/dt 70 kA/us, Coil diameter 8 mm; length 700 mm |
| RCP6000L-700 Rogowski current probe. Peak Current 6000 Apk, 3 Hz - 10 MHz, Sensitivity 1 mV/A (1000X), Peak di/dt 70 kA/us, Coil diameter 8 mm; length 700 mm |
| RCP12000L-700 Rogowski current probe. Peak Current 12000 Apk, 2 Hz-10 MHz, Sensitivity 0.5 mV/A (2000X), Peak di/dt 70 kA/us, Coil diameter 8 mm; length 700 mm |