PicoScope 4444 1000 V CAT III differential oscilloscope kit

High-resolution differential oscilloscope with three PicoConnect 442 1000 V CAT III passive differential voltage probes and one TA271 single-ended D9-BNC adaptor

Key features

  • 4 fully differential high-impedance inputs
  • 20 MHz bandwidth
  • Flexible 12 and 14-bit resolution
  • 256 MS deep memory
  • Rejects common-mode noise
  • Interface for intelligent probes and clamps
  • Low-voltage probe for millivolts to 50 V
  • 1000 V CAT III probe for high-voltage applications

Typical applications

  • Non-ground-referenced measurements
  • Safe probing of single-phase and three-phase voltages and currents
  • Measuring power drawn by mobile and IoT devices
  • Mains quality testing
  • SMPS design
  • Hybrid and electric vehicle design
  • Motor drives and inverters
  • Biomedical electronics
  • Measuring differential signals (CAN, balanced audio) with a single channel
Price
 
kr 13.964*
* excluding VAT free shipping (Denmark)

Product Number:

PICO-PQ074

Manufacturer:

Picotech

Quantity:

Total
Unit price
base price
Stock
Typically on stock
Quick delivery

High-end oscilloscope

At the heart of every PicoScope 4444 is an advanced oscilloscope that offers everything you would expect and much more, including:

  • 10 000 waveform circular buffer
  • Up to 100 000 waveforms per second update rate
  • Serial bus decoding
  • Mask limit testing
  • Advanced math and filtering
  • Measurements with statistics
  • Advanced digital triggering
  • USB 3.0 connected and powered

Intelligent differential inputs

With a traditional oscilloscope probe, single-ended measurements are made between a high-impedance input and a low-impedance ground.

With a differential oscilloscope, measurements are made between two high-impedance inputs, allowing measurements to be made across components and test points where neither side is grounded. Differential inputs also reject common-mode noise: noise picked up equally on both high-impedance inputs is rejected.

Each of the four input channels on the PicoScope 4444 features an intelligent probe interface that detects and identifies compatible probes, and powers them where necessary. Each channel can have its own choice of voltage or current probe.

Non-attenuating probes allow high-resolution, low-noise measurement of signals ranging from millivolts to ±50 V. Attenuating probes allow signals up to 1000 V CAT III to be measured. Current probes are available for currents up to 2000 A.

Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha
Description
Reviews
Query on the Item

High-end oscilloscope

At the heart of every PicoScope 4444 is an advanced oscilloscope that offers everything you would expect and much more, including:

  • 10 000 waveform circular buffer
  • Up to 100 000 waveforms per second update rate
  • Serial bus decoding
  • Mask limit testing
  • Advanced math and filtering
  • Measurements with statistics
  • Advanced digital triggering
  • USB 3.0 connected and powered

Intelligent differential inputs

With a traditional oscilloscope probe, single-ended measurements are made between a high-impedance input and a low-impedance ground.

With a differential oscilloscope, measurements are made between two high-impedance inputs, allowing measurements to be made across components and test points where neither side is grounded. Differential inputs also reject common-mode noise: noise picked up equally on both high-impedance inputs is rejected.

Each of the four input channels on the PicoScope 4444 features an intelligent probe interface that detects and identifies compatible probes, and powers them where necessary. Each channel can have its own choice of voltage or current probe.

Non-attenuating probes allow high-resolution, low-noise measurement of signals ranging from millivolts to ±50 V. Attenuating probes allow signals up to 1000 V CAT III to be measured. Current probes are available for currents up to 2000 A.

Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha