We use cookies in order to guarantee the best possible service. If you continue browsing the site you consent to our cookie use.

Keysight S96089B Differential and I/Q device measurements

Key Features

The S96089B combines source-phase control of multiple internal or external sources with frequency-offset mode, enabling simplified test of I/Q modulators/converters, differential mixers, and harmonics or amplifiers.

  • Works with the E5080B ENA and E5081A ENA-X Analyzers
  • Control the phase of multiple signal sources for quadrature or differential drive accurately, eliminating the need for hybrid couplers and baluns
  • Tune receivers to all output frequencies required to fully characterize the DUT
  • Sweep frequency with a fixed phase offset, or sweep phase or power at a fixed frequency
  • Measure I/Q converters/modulators, differential mixers, or harmonics of differential amplifiers
  • S96089B only works on 4-port ENA-X or E5080B ENA with 2nd source options.

Additional Documents:

Product Number:

S96089B

Manufacturer:

Keysight Technologies

Quantity:

Total
Unit price
base price
Stock
Call or email for delivery time

The S96089B combines source-phase control of multiple internal or external sources with frequency-offset mode, enabling simplified test of I/Q modulators/converters and differential mixers, and harmonic measurements of differential amplifiers. The phase difference between sources can be fixed (for example, at 90 or 180 degrees), or swept between two specified phase values. Providing accurate control of the relative phase between sources eliminates the need for hybrid couplers and baluns to create quadrature or differential signals. After achieving the desired phase alignment, the instrument's receivers can be tuned to all frequencies needed to characterize the DUT. On an I/Q modulator for example, measurements can be made of both the desired and suppressed conversion bands, along with LO leakage, harmonics and other spurious signals. Phase sweeps can be used to determine a DUT’s phase imbalance versus frequency. Users can specify measurements with individual receivers or multiple receivers combined with a wide range of mathematical operators. Power measurements can employ match correction for increased accuracy.

Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha
Description
Reviews
Query on the Item

The S96089B combines source-phase control of multiple internal or external sources with frequency-offset mode, enabling simplified test of I/Q modulators/converters and differential mixers, and harmonic measurements of differential amplifiers. The phase difference between sources can be fixed (for example, at 90 or 180 degrees), or swept between two specified phase values. Providing accurate control of the relative phase between sources eliminates the need for hybrid couplers and baluns to create quadrature or differential signals. After achieving the desired phase alignment, the instrument's receivers can be tuned to all frequencies needed to characterize the DUT. On an I/Q modulator for example, measurements can be made of both the desired and suppressed conversion bands, along with LO leakage, harmonics and other spurious signals. Phase sweeps can be used to determine a DUT’s phase imbalance versus frequency. Users can specify measurements with individual receivers or multiple receivers combined with a wide range of mathematical operators. Power measurements can employ match correction for increased accuracy.

Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha