Haefely-DEC 7 Decoupling Network for testing asymmetrically operated lines with Surge, Ring Wave 100 kHz, max. 4 wires

Price
 
kr 36.401*
* excluding VAT free shipping (Denmark)

Product Number:

Haefely-DEC7

Manufacturer:

Haefely

Quantity:

Total
Unit price
base price
Stock
Call or email for delivery time

The DEC 7 is used for decoupling auxiliary equipment from an EUT tested with either 1,2/50ms-8/20ms combination wave impulses or ring wave 100kHz impulses up to 6.6kV peak. It is used to decouple unshielded asymmetrical control and data lines according IEC/EN standards. Up to 4 wires can be tested simultaneously.

To obtain maximum flexibility only decoupling and protection elements are included in the DEC 7. Coupling circuits, which depends on the EUT to be tested, can be placed separately in the test setup. Manual coupling selection of the protection elements for best protection of the auxiliary equipment.

Default protection elements are varistors and breakdown avalanche diodes (ABDs). With such elements, the capacitive load to the EUT lines is small. The decoupling elements can be selected easily. It is also possible to test without any protection elements.

Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha
Description
Reviews
Query on the Item

The DEC 7 is used for decoupling auxiliary equipment from an EUT tested with either 1,2/50ms-8/20ms combination wave impulses or ring wave 100kHz impulses up to 6.6kV peak. It is used to decouple unshielded asymmetrical control and data lines according IEC/EN standards. Up to 4 wires can be tested simultaneously.

To obtain maximum flexibility only decoupling and protection elements are included in the DEC 7. Coupling circuits, which depends on the EUT to be tested, can be placed separately in the test setup. Manual coupling selection of the protection elements for best protection of the auxiliary equipment.

Default protection elements are varistors and breakdown avalanche diodes (ABDs). With such elements, the capacitive load to the EUT lines is small. The decoupling elements can be selected easily. It is also possible to test without any protection elements.