We use cookies in order to guarantee the best possible service. If you continue browsing the site you consent to our cookie use.

GW-INSTEK PPH-1506D (CE) Programmable High Precision Linear D.C. Power Supply

Key Features and Functions

  • Dual Channel DC Power Output
  • PPH-1506D (CH1: 0~15V/0~3A or 0~9V/0~5A; CH2: 0~12V/0~3A)
  • 3.5 inch TFT LCD Display
  • Built-in DVM Measurement Function
  • High Measurement Resolution (1mV/0.1μA for 5mA Range)
  • Current Sink Function (Maximum : 3.5A)
  • Pulse Current Measurement
  • Long Integration Current Measurement
  • Sequence Function (Sequential power output)
  • Built-in Battery Simulation Function
  • OVP, OCP, OTP & Temperature Display for Heat Sink
  • Support USB (Device& Host)/GPIB/LAN
  • 5 Groups of Save/Recall Setting
  • External RELAY Control

Documents and Software Solutions:

Price
 
kr 19.857*
* excluding VAT free shipping (Denmark)

Product Number:

GW-PPH-1506D_CE_

Manufacturer:

GW-INSTEK

Quantity:

Total
Unit price
base price
Stock
Typically on stock
Quick delivery

PPH-15xxD high precision measurement capability achieves the maximum resolution of 1mV/0.1uA and the smallest pulse current width of 33us that satisfy customers’ measurement application requirements of high resolution and pulse current. Fast load current variation will result in voltage sag for general power supplies that will have an impact on DUT’s internal circuit operation. PPH-15xxD is equipped with the excellent transient recovery time, which can, in less than 40us, recover the output voltage to within 100mV of the previous voltage output when the current level changes from 10% to 100% of the full scale. Furthermore, conventional power supplies do not have sufficient response speed to promptly respond to set voltage value once the set voltage is changed. PPH-15xxD has a rise time of 0.2ms and a fall time of 0.3ms, which are 100 times faster than that of conventional power supplies. Therefore, PPH-15xxD can provide DUT with a stable output voltage even when DUT is operating under large transient current output. The internal high-speed sampling circuit design of PPH-15xxD, with the sample rate of 64K, can conduct pulse current measurement without using a current probe and oscilloscope. The current read back accuracy is 0.2%+1uA (equals to 11uA) at 5mA range, and the read back resolution is 0.1uA that allow DUT to be measured with a high accuracy level. 

Channel Configuration: 

Model

PPH-1503

PPH-1503D

PPH-1506D

PPH-1510D

Number of output channel

1

2

2

2

Channel No.

Ch1

Ch1

Ch2

Ch1

Ch2

Ch1

Ch2

Power

45W

45W

18W

45W

36W

45W

36W

Voltage

0 ~ 15V or 0 ~ 9V

0 ~ 15V or 0 ~ 9V

0 ~ 12V

0 ~ 15V or 0 ~ 9V

0 ~ 12V

0 ~ 15V or 0 ~ 9V

0 ~ 12V

Current

0 ~ 3A or 0 ~ 5A

0 ~ 3A or 0 ~ 5A

0 ~ 1.5A

0 ~ 3A or 0 ~ 5A

0~ 3.0A  

0 ~ 3A or 0 ~ 5A;

Rear: 0~10A(under 0~

4.5V) 

 0~ 3.0A

Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha
Description
Reviews
Query on the Item

PPH-15xxD high precision measurement capability achieves the maximum resolution of 1mV/0.1uA and the smallest pulse current width of 33us that satisfy customers’ measurement application requirements of high resolution and pulse current. Fast load current variation will result in voltage sag for general power supplies that will have an impact on DUT’s internal circuit operation. PPH-15xxD is equipped with the excellent transient recovery time, which can, in less than 40us, recover the output voltage to within 100mV of the previous voltage output when the current level changes from 10% to 100% of the full scale. Furthermore, conventional power supplies do not have sufficient response speed to promptly respond to set voltage value once the set voltage is changed. PPH-15xxD has a rise time of 0.2ms and a fall time of 0.3ms, which are 100 times faster than that of conventional power supplies. Therefore, PPH-15xxD can provide DUT with a stable output voltage even when DUT is operating under large transient current output. The internal high-speed sampling circuit design of PPH-15xxD, with the sample rate of 64K, can conduct pulse current measurement without using a current probe and oscilloscope. The current read back accuracy is 0.2%+1uA (equals to 11uA) at 5mA range, and the read back resolution is 0.1uA that allow DUT to be measured with a high accuracy level. 

Channel Configuration: 

Model

PPH-1503

PPH-1503D

PPH-1506D

PPH-1510D

Number of output channel

1

2

2

2

Channel No.

Ch1

Ch1

Ch2

Ch1

Ch2

Ch1

Ch2

Power

45W

45W

18W

45W

36W

45W

36W

Voltage

0 ~ 15V or 0 ~ 9V

0 ~ 15V or 0 ~ 9V

0 ~ 12V

0 ~ 15V or 0 ~ 9V

0 ~ 12V

0 ~ 15V or 0 ~ 9V

0 ~ 12V

Current

0 ~ 3A or 0 ~ 5A

0 ~ 3A or 0 ~ 5A

0 ~ 1.5A

0 ~ 3A or 0 ~ 5A

0~ 3.0A  

0 ~ 3A or 0 ~ 5A;

Rear: 0~10A(under 0~

4.5V) 

 0~ 3.0A

Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha