SPECIFICATIONS

  • Resolution: 640 × 512
  • Detector Pitch: 15 µm
  • Spectral Range: 3.0 – 5.0 µm
  • Detector Type: FLIR indium antimonide (InSb)
  • Camera f-number: f/4.0
  • Dynamic Range: 14-bit
  • Frame Rate [Full Window]: Programmable 0.0015 Hz to 125 Hz
  • Integration Time: 480 ns to ~full frame
  • Standard Temperature Range: 0°C to 350°C (32°F to 662°F)
  • Optional Temperature Range: Using ND filters up to 3000°C
  • Focus: Motorized FOV/focus

IMAGING & OPTICAL

  • Camera f-number: f/4.0
  • Detector Pitch: 15 µm
  • Detector Type: FLIR indium antimonide (InSb)
  • Digital Zoom: 1x, Auto (best fit), off
  • Dynamic Range: 14-bit
  • Focus: Motorized FOV/focus
  • Frame Rate [Full Window]: Programmable 0.0015 Hz to 125 Hz
  • Image Time Stamp: Internal precision timestamp, IRIG-B AM decoder, TSPI accurate
  • Integration Time: 480 ns to ~full frame
  • Lens: 50-250 mm continuous metric zoom - low latency metadata (with 3x afocal optional attachment - 150-750 mm)
  • Lens Cover: Optional, motorized
  • On Camera Image Storage: None
  • Operability: ≥99.95% typical
  • Overlay: Customizable (ability to toggle off)
  • Palette: Selectable 8-bit
  • Pixel Clock: 50 MHz
  • Radiometric Data Streaming: Gigabit Ethernet (GigE Vision), CoaXPress Single Link 1.1
  • Readout Modes: Asynchronous integrate while read, asynchronous integrate then read
  • Readout Type: Snapshot
  • Resolution: 640 × 512
  • Sensor Cooling: Closed-cycle rotary
  • Spectral Range: 3.0 – 5.0 µm
  • Standard Video: SDI
  • Subwindow Modes: Flexible windowing down to 16 × 4 (steps of 16 columns, 4 rows)
  • Thermal Sensitivity_NETD [typical]: 27 mK typical
  • Video Modes: SDI: 720p@50/59.9, 1080p@25/29.9, 480i@60 Hz, 576i@50 Hz

MEASUREMENT & ANALYSIS

  • Accuracy: ≤100°C ±2°C (±1°C typical), >100°C ±2% of reading (±1% typical)
  • Ambient Drift Compensation [with factory cal]: Yes
  • Automatic Gain Control: Manual, Linear, Plateau equalization, DDE
  • Optional Temperature Range: Using ND filters up to 3000°C
  • Standard Temperature Range: 0°C to 350°C (32°F to 662°F)

COMMUNICATION & DATA STORAGE

  • Command and Control: GigE, CoaXPress (GenICam protocol supported over GigE or CXP), RS-232
  • Synchronization Modes: Sync In, Sync Out, Tri-Level Sync, IRIG, Lock-In
  • Trigger Mode(s): Trigger in, header based

Documents and Software Solutions:

Product Number:

FLIR-RS6780

Manufacturer:

FLIR

Quantity:

Total
Unit price
base price
Stock
Call or email for delivery time

The FLIR RS6780 offers advanced detector, triggering, and synchronization capabilities in an environmentally protected package, making it easy to configure and integrate for successful data acquisition in the most demanding R&D applications. With a three-position motorized filter wheel and continuous metric zoom (CZ) lens, the RS6780 records sharply focused, high-quality thermal images in long-range and tracking applications. The standard 50-250 mm CZ lens can be factory-calibrated for temperature and radiance measurements, allowing researchers to use the radiometric camera system without sacrificing the flexibility of the optics platform.

SUPERIOR MEASUREMENT ACCURACY

Capture crisp thermal images of high-temperature targets with 640 x 512 resolution, a three-position filter wheel, and continuous metric zoom lens

FLEXIBLE

Synchronize the camera with external events or instrumentation, control precisely when an image frame is generated with advanced triggering, and embed TSPI-accurate data timestamping

SMALL AND RUGGED

Easily integrate this lightweight system indoors or outdoors – the IP65 weatherproof enclosure provides protection in the harshest environments

Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha
Description
Reviews
Query on the Item

The FLIR RS6780 offers advanced detector, triggering, and synchronization capabilities in an environmentally protected package, making it easy to configure and integrate for successful data acquisition in the most demanding R&D applications. With a three-position motorized filter wheel and continuous metric zoom (CZ) lens, the RS6780 records sharply focused, high-quality thermal images in long-range and tracking applications. The standard 50-250 mm CZ lens can be factory-calibrated for temperature and radiance measurements, allowing researchers to use the radiometric camera system without sacrificing the flexibility of the optics platform.

SUPERIOR MEASUREMENT ACCURACY

Capture crisp thermal images of high-temperature targets with 640 x 512 resolution, a three-position filter wheel, and continuous metric zoom lens

FLEXIBLE

Synchronize the camera with external events or instrumentation, control precisely when an image frame is generated with advanced triggering, and embed TSPI-accurate data timestamping

SMALL AND RUGGED

Easily integrate this lightweight system indoors or outdoors – the IP65 weatherproof enclosure provides protection in the harshest environments

Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha