We use cookies in order to guarantee the best possible service. If you continue browsing the site you consent to our cookie use.

AR-125S1G6 125 Watt CW, 0.7 - 6 GHz

RATED POWER OUTPUT: 125 watts minimum (0.7-6GHz)

POWER OUTPUT @ 3dB COMPRESSION Nominal, 125 watts; Minimum, 120 watts

POWER OUTPUT @ 1dB COMPRESSION Nominal, 120 watts; Minimum, 100 watts

SMALL SIGNAL GAIN FLATNESS: ±1.5 dB typical; ±2.0 dB maximum

FREQUENCY RESPONSE: 0.7–6GHz instantaneously

INPUT FOR RATED OUTPUT: 1.0 milliwatt maximum

GAIN (at maximum setting): 52 dB minimum

GAIN ADJUSTMENT (Continuous Range): 10 dB minimum (4096 steps remote)

INPUT IMPEDANCE: 50 ohms, VSWR 2.0:1 maximum

OUTPUT IMPEDANCE: 50 ohm nominal

MISMATCH TOLERANCE:
100% of rated power without foldback. Will operate without damage or oscillation with any magnitude and phase of source and load impedance. See Application Note #27.

MODULATION CAPABILITY: Will faithfully reproduce AM, FM, or pulse modulation appearing on the input signal

HARMONIC DISTORTION: -20 dBc maximum at 125 W

THIRD ORDER INTERCEPT POINT: 58 dBm typical

Remote Interfaces:

  • IEEE-488, 24 pin female
  • RS-232, 9 pin Subminiature D (female)
  • Fiber Optic, ST Conn Tx and Rx RS-232
  • USB 2.0, Type B
  • Ethernet, RJ-45

 

Product Number:

AR-125S1G6

Manufacturer:

Amplifier Research

Quantity:

Total
Unit price
base price
Stock
Call or email for delivery time

The Model 125S1G6 is a solid-state, Class A design, self-contained, air-cooled, broadband amplifier designed for applications where instantaneous bandwidth, high gain and linearity are required. Housed in a stylish contemporary cabinet, the unit is designed for benchtop use, but can be removed from the cabinet for immediate equipment rack mounting.

The 125S1G6, when used with a sweep generator, will provide a minimum of 125 watts of RF power. Included is a front panel gain control which permits the operator to conveniently set the desired output level. The 125S1G6 is protected from RF input overdrive by an RF input leveling circuit which controls the RF input level to the RF amplifier first stage when the RF input level is increased above 0 dBm. The RF amplifier stages are protected from over-temperature by removing the DC voltage to them if an over-temperature condition occurs due to cooling blockage or fan failure. There is a digital display on the front panel to indicate the operate status and fault conditions if an overtemperature or power supply fault has occurred.

The unit can be returned to operate when the condition has been cleared. All amplifier control functions and status indications are available remotely in GPIB/IEEE-488 format, RS-232 hardwire and fiber optic, USB, and Ethernet. The bus interface connector is located on the back panel and positive control of local or remote operation is assured by a Local/Remote switch on the front panel of the amplifier.

Description
Additional Informations
Reviews
Query on the Item
Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here
captcha
Description
Reviews
Query on the Item

The Model 125S1G6 is a solid-state, Class A design, self-contained, air-cooled, broadband amplifier designed for applications where instantaneous bandwidth, high gain and linearity are required. Housed in a stylish contemporary cabinet, the unit is designed for benchtop use, but can be removed from the cabinet for immediate equipment rack mounting.

The 125S1G6, when used with a sweep generator, will provide a minimum of 125 watts of RF power. Included is a front panel gain control which permits the operator to conveniently set the desired output level. The 125S1G6 is protected from RF input overdrive by an RF input leveling circuit which controls the RF input level to the RF amplifier first stage when the RF input level is increased above 0 dBm. The RF amplifier stages are protected from over-temperature by removing the DC voltage to them if an over-temperature condition occurs due to cooling blockage or fan failure. There is a digital display on the front panel to indicate the operate status and fault conditions if an overtemperature or power supply fault has occurred.

The unit can be returned to operate when the condition has been cleared. All amplifier control functions and status indications are available remotely in GPIB/IEEE-488 format, RS-232 hardwire and fiber optic, USB, and Ethernet. The bus interface connector is located on the back panel and positive control of local or remote operation is assured by a Local/Remote switch on the front panel of the amplifier.

Do you have any questions on this item?
Your E-mail Address
My Question:
Please retype the letters shown here